Search results for "Radiographic image interpretation"
showing 10 items of 44 documents
Volume stability of hydroxyapatite and β-tricalcium phosphate biphasic bone graft material in maxillary sinus floor elevation: a radiographic study u…
2015
Objectives The purpose of this study was to confirm volume stability of biphasic calcium phosphate (BCP) through the changes of grafted volume over the time by 3D CT analyzing software program. Patients and Methods Fifteen patients, 16 sinuses who were scheduled a staged implantation through sinus floor elevation (SFE)–lateral window technique from 2009 to 2011 were included in the study. Of the 15 patients, eight were male and seven were female (mean age 50.1). For sinus floor augmentation, BCP with local blood was packed loosely into the maxillary sinus and the grafted site was covered with a collagen membrane. For the evaluation of volume change, 3D CBCT scans were taken five times at pr…
MAGIC-5: an Italian mammographic database of digitised images for research
2008
The implementation of a database of digitised mammograms is discussed. The digitised images were collected beginning in 1999 by a community of physicists in collaboration with radiologists in several Italian hospitals as a first step in developing and implementing a computer-aided detection (CAD) system. All 3,369 mammograms were collected from 967 patients and classified according to lesion type and morphology, breast tissue and pathology type. A dedicated graphical user interface was developed to visualise and process mammograms to support the medical diagnosis directly on a high-resolution screen. The database has been the starting point for developing other medical imaging applications,…
Focal confluent fibrosis in cirrhotic liver: natural history studied with serial CT.
2009
The objective of this study was to assess the long-term natural history of focal confluent fibrosis in cirrhotic liver with CT.Two radiologists retrospectively reviewed in consensus 118 liver CT examinations in 26 patients (19 men, seven women; age range, 32-68 years; mean age, 50 years) performed over approximately 6 years. Helical CT scans were obtained before and 30-35 and 65-70 seconds after injection of 125-150 mL of contrast medium at a rate of 4-5 mL/s. Proof of cirrhosis was based on liver transplantation (n = 6), biopsy (n = 9), or imaging findings (n = 11). The number, location, and attenuation of fibrotic lesions and presence of trapped vessels were evaluated. Variation of hepati…
Virtual Unenhanced Images at Dual-Energy CT: Influence on Renal Lesion Characterization
2019
Background Dual-energy (DE) CT allows reconstruction of virtual noncontrast (VNC) images from a single-phase contrast agent-enhanced examination, potentially reducing the need for multiphasic CT to characterize renal lesions. However, data regarding diagnostic performance of VNC images for the characterization of renal lesions are limited. Purpose To determine whether renal mass CT performed by using VNC images allows for reliable identification of renal lesions and differentiation of contrast-enhanced from unenhanced lesions, compared with unenhanced images. Materials and Methods This is a retrospective study of 293 patients (105 women [mean age, 65 years; age range, 18-91 years] and 188 m…
Efficacy of single-source rapid kV-switching dual-energy CT for characterization of non-uric acid renal stones: a prospective ex vivo study using ant…
2019
Purpose To investigate the accuracy of rapid kV-switching single-source dual-energy computed tomography (rsDECT) for prediction of classes of non-uric-acid stones. Materials and methods Non-uric-acid renal stones retrieved via percutaneous nephrolithotomy were prospectively collected between January 2017 and February 2018 in a single institution. Only stones >= 5 mm and with pure composition (i.e., >= 80% composed of one component) were included. Stone composition was determined using Fourier Transform Infrared Spectroscopy. The stones were scanned in 32-cm-wide anthropomorphic whole-body phantom using rsDECT. The effective atomic number (Zeff), the attenuation at 40 keV (HU40), 70 ke…
Quantitative analysis of emphysema in 3D using MDCT: Influence of different reconstruction algorithms
2008
Abstract Purpose The aim of the study was to compare the influence of different reconstruction algorithms on quantitative emphysema analysis in patients with severe emphysema. Material and methods Twenty-five patients suffering from severe emphysema were included in the study. All patients underwent inspiratory MDCT (Aquilion-16, slice thickness 1/0.8 mm). The raw data were reconstructed using six different algorithms: bone kernel with beam hardening correction (BHC), soft tissue kernel with BHC; standard soft tissue kernel, smooth soft tissue kernel (internal reference standard), standard lung kernel, and high-convolution kernel. The only difference between image data sets was the algorith…
Characterization of Small Incidental Indeterminate Hypoattenuating Hepatic Lesions: Added Value of Single-Phase Contrast-Enhanced Dual-Energy CT Mate…
2018
OBJECTIVE. The objective of this study is to determine whether single-phase contrast-enhanced dual-energy CT (DECT) material attenuation analysis improves the characterization of small (< 2.0 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional single-energy CT evaluation. MATERIALS AND METHODS. This retrospective study involved 55 patients (24 men and 31 women; mean [± SD] age, 63.9 ± 15.3 years) with 77 incidental hypoattenuating hepatic lesions (59 benign and 18 malignant lesions) measuring 0.5–2.0 cm who underwent single-phase contrast-enhanced DECT of the abdomen for pain. For each lesion, attenuation measurements were obtained using blended 120-k…
Diagnostic performance of reformatted isotropic thin-section helical CT images in the detection of superior semicircular canal dehiscence
2017
Purpose The purpose of this article is to assess the diagnostic performance of computed tomography (CT) reformatted images for detection of superior semicircular canal (SSC) dehiscence. Material and methods Forty-two patients, with sound- and/or pressure-induced vestibular symptoms, and 42 control participants underwent helical CT examination with a highly collimated beam (0.5 mm). Reformatted images of the vestibular labyrinth were obtained in the standard axial and coronal planes (group A images), and in a plane parallel and perpendicular to the SSC (group B images). Diagnostic performance obtained by evaluating the group A images alone and the group B images alone was analyzed by using t…
Automatic detection and quantification of ground-glass opacities on high-resolution CT using multiple neural networks: comparison with a density mask.
2000
We compared multiple neural networks with a density mask for the automatic detection and quantification of ground-glass opacities on high-resolution CT under clinical conditions.Eighty-four patients (54 men and 30 women; age range, 18-82 years; mean age, 49 years) with a total of 99 consecutive high-resolution CT scans were enrolled in the study. The neural network was designed to detect ground-glass opacities with high sensitivity and to omit air-tissue interfaces to increase specificity. The results of the neural network were compared with those of a density mask (thresholds, -750/-300 H), with a radiologist serving as the gold standard.The neural network classified 6% of the total lung a…
Validation of tumour-free distance as novel prognostic marker in early-stage cervical cancer: a retrospective, single-centre, cohort study
2021
Background: The aim of the present study was to assess the prognostic value of tumour-free distance (TFD), defined as the minimum distance of uninvolved stroma between the tumour and peri-cervical stromal ring, in early-stage cervical cancer. Methods: Patients with pathologic FIGO 2009 stage IA1–IIA2 cervical cancer, treated by primary radical surgical treatment between 01/2000 and 11/2019, were retrospectively included. Adjuvant treatment was administered according to the presence of previously established pathologic risk factors. TFD was measured histologically on the hysterectomy specimen. Pre-operative TFD measured at MRI-scan from a cohort of patients was reviewed and compared with pat…